www.opti-ups.com
Placement
This UPS is intended for indoor use
only; its internal components are not
sealed from the environment.
Please install it in a protected
environment away from excessive heat
or excessive moisture.
Connecting your equipment to the UPS
For all UPS models except the version with IEC outlets: connect the power cord(s) of
your computer equipment to the output receptacle(s) of the UPS.
For UPS with IEC outlets, as shown in the illustration, use your computer power cord
to connect UPS to the wall socket. Use the power cord supplied with the UPS to
connect your PC to one of UPS outlets.
Turn on the UPS
To turn UPS on please press the power button for 3 seconds. Pressing the power
button shortly under normal mode will enable the self-test function. The silence
function can be enabled/disabled by shortly pressing the power button in backup
mode. In addition, the power button can be used as the master on/off switch for your
equipment by leaving your equipment connected to UPS and switched on. To turn off
the UPS, please press power button for about 3 seconds.
Front & Rear Panels
1.1 Power Button
1.2 RS-232 Port
*)
1.3 Phone/LAN Jack
*)
1.4 AC Input
1.5 UPS Outlets
1.6 AC Fuse
*)
TS-B models only
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This Manual contains important instructions that should be followed during installation and maintenance
of the UPS and batteries.
Intended for installation in a controlled environment.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the
required precautions. Keep unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and type.
CAUTION - Do not dispose of battery or batteries in a fire. The battery may explode."
CAUTION - Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin
and eyes. It may be toxic.
CAUTION - A battery can present a risk of electrical shock and high short circuit current. The
following precautions should be observed when working on batteries:
- Remove watches, rings, or other metal objects.
- Use tools with insulated handles.
- Wear rubber gloves and boots.
- Do not lay tools or metal parts on top of batteries.
- Disconnect charging source prior to connecting or disconnecting battery terminals.
No Load Shutdown Function
As a battery saving feature, the UPS will automatically turn off if none of the connected equipment
is operating while the UPS is in back-up mode. Once normal utility power returns, the unit will
re-start automatically. You can disable the “No Load Shutdown” function by pressing the power
button of your switched-off UPS until you hear two beeps.
Front panel LED (UPS status indicator)
AC Mode
When the LED is continuously lit and the buzzer is silent, the UPS is in
normal mode and providing power to your equipment. The UPS will
continue to filter electrical noise and provide surge protection.
Battery Mode
When the LED blinks every 2 seconds in time with the beeping sound, the
UPS is providing power from its battery.
Fault
When the LED is flashing rapidly and the beeping sound is continuous, it
indicates that the UPS is overloaded.
Warning
DO NOT PLUG LASER PRINTERS INTO THE UPS BECAUSE
THEY TYPICALLY DRAW TOO MUCH POWER
Fuse replacement procedure
1. Use a slotted screwdriver to take out the fuse holder
2. Take out the busted fuse from the fuse holder
3. Use the screwdriver to push out the spare fuse from the holder
4. Put the spare fuse in the holder
5. Push the fuse holder back into the AC input socket
6. Follow the UPS turn on procedure
Fuse
Holder
Charging the UPS first
The battery is fully charged at the
factory. However, it is recommended
to charge the battery at least 8 (eight)
hours before using the UPS, since
energy loss may have occurred during
shipping or long duration storage. To
recharge the battery, simply leave the
UPS plugged into an AC outlet.
Vue de la page 0
1 2

Résumé du contenu

Page 1 - SAVE THESE INSTRUCTIONS

www.opti-ups.com Placement This UPS is intended for indoor use only; its internal

Page 2 - Contact Information

Specifications Model TS 400 TS 500(B) TS 650(B) TS 1000(B) Maximum Capacity 240W 300W 3